Guide · Cold roofs
Loose-fill fibreglass vs cellulose fibre in the cold
When the US Department of Energy’s Oak Ridge laboratory chilled a full-size roof space (attic), cellulose fibre insulation gained R-value as it got colder (R-18 to R-20.3) while the loose-fill fibreglass it tested lost about 35 to 50% at the coldest test conditions. The coldest night of the year is the night your insulation matters most, so ask any installer of blown-in fibreglass for the cold test on their product before it goes in.
Every figure on this page comes from the published papers, with the product, the conditions and the page beside it.
Get a fixed-price quote →
I’m Peter Johnson. I did my first insulation job with my dad in 1988, labouring and filling the hopper, and I’ve been in the industry ever since. We make and pump in our own premium cellulose insulation and we fit batts as well, and every winter someone up the range asks me whether blown-in fibreglass will hold up on a frosty night. The US Department of Energy’s laboratory answered that question with a thermometer and a full-size roof space, so here are its numbers. For the batts side of the question, see our full cellulose versus fibreglass comparison.
What the cold roof test found
Cellulose fibre insulation gained R-value as the roof space got colder, from R-18 with the outside air at 4°C to R-20.3 at −28°C (Energy Design Update, October 1991, pages 4 to 6, reporting the Oak Ridge test).
The loose-fill fibreglass tested started losing R-value once the roof space was about 18°C colder than the room below, and at a 39 to 42°C difference its thermal resistance “was about 35% to 50% less than at small temperature differences” (Wilkes and Childs, Oak Ridge National Laboratory, 1992, Abstract).
The loss was measured in loose-fill fibreglass only. The paper’s own words: “No significant convection was found either with fiberglass batts” or with the one loose-fill cellulose fibre insulation tested (Abstract). The authors also wrote that similar curves had been seen for “some other (but not all)” loose-fill fibreglass products of the day (section “Loose-Fill Fiberglass Insulation Only”), so the result is for the products tested, not every blown-in fibreglass.
Those were 1991 products. The manufacturers say today’s loose-fill fibreglass is redesigned, so the thing to ask for is a cold test on the exact product offered to you, which is covered below.
About this test
Show the test details
- Who, for whom: K.E. Wilkes and P.W. Childs, Oak Ridge National Laboratory, for the US Department of Energy, with support from Attic Seal Inc. and the Cellulose Industry Standards Enforcement Program (so the cellulose industry co-funded it). ASHRAE/DOE/BTECC conference, December 1992; tests 1991 to 1992.
- Product tested: one type of loose-fill fibreglass, new, four specimens from two production lots, blown in by a local contractor at 6.4 to 9.0 kg/m³ (Table 1); unfaced R-19 fibreglass batts at 7.4 to 7.7 kg/m³; one loose-fill cellulose fibre insulation, new, installed at 30 kg/m³ and tapped down to 34 kg/m³. No brand is named in the paper.
- Conditions: the DOE Large Scale Climate Simulator: a 14 ft by 16 ft roof-space module with a plasterboard ceiling, ventilated, room below at 21°C, outside chamber held at steady settings from 7°C down to −28°C, each run about 24 hours.
- Result: the R-19 loose-fill fibreglass fell from about R19 at small differences to R10.5 at a 42°C difference; the R-38 specimen fell from about R38 to R21. The batts and the cellulose fibre held or rose slightly as it got colder (Table 3).
- What it does not show: today’s products, Australian products, batts losing R-value, or a summer roof.
- Source: Wilkes and Childs 1992, “Thermal Performance of Fiberglass and Cellulose Attic Insulations”, Abstract; Tables 1 and 3; sections “Loose-Fill Fiberglass Insulation Only” and “Loose-Fill Cellulose Insulation”.
About the 1991 report
Show the test details
- Who, for whom: two tests reported by Energy Design Update, October 1991. (1) The University of Illinois Building Research Council, sponsored by a fibreglass manufacturer, in a test building with heat-flux sensors. (2) Oak Ridge National Laboratory, in the climate simulator above, with the cellulose fibre insulation test commissioned by the Cellulose Industry Standards Enforcement Program.
- Product tested: (1) a nominal R-34, 14-inch layer of loose-fill fibreglass, new. (2) a cubed loose-fill fibreglass, new, and a loose-fill cellulose fibre insulation at 37 to 38 kg/m³, new. The article names the fibreglass brands; we leave them out because the 1991 products are not the products sold today.
- Conditions: (1) house at 21°C, roof space tracking outdoor temperatures from −18°C to 3°C over one January. (2) room at 21°C, outside from 4°C to −28°C.
- Result: (1) the fibreglass performed as expected until the roof space fell to about −1°C; at −12°C its effective R-value “dropped over 50%”. (2) The cubed fibreglass lost 40% to 50% of its R-value at the coldest settings; the cellulose fibre insulation rose from R-18 at 4°C to R-20.3 at −28°C. The Illinois batts “showed no evidence of convection or loss of R-value”.
- What it does not show: today’s products, or lightweight cellulose at 26 to 27 kg/m³ (the article says there was no test data for it).
- Source: Energy Design Update, Oct 1991, “Loose-Fill Fiberglass Versus Cellulose in Cold Attics”, pages 4 to 6.
R-value against the temperature difference, room to roof space
- Loose-fill fibreglass, R-19 label (LF-3): R19.4 down to R10.5
- R-19 fibreglass batts: R19.4 to R20.4
- Cellulose fibre insulation, as blown: R20.1 to R21.8
- Cellulose fibre insulation, “settled”: R18.1 to R20.4
- 39 to 42°C difference band
Reading the graph. Each line is one specimen in the same roof-space module at the same settings. The loose-fill fibreglass line is flat until the top of the insulation is about 18°C colder than the room, then falls as the air inside it starts to circulate. The batts and the cellulose fibre insulation lines hold or rise slightly as it gets colder. The numbers are the paper’s Table 3; the graph is ours, drawn from that table.
What the manufacturers say
Convection can reduce performance, say manufacturers
Owens Corning’s attic card for its PROPINK L77 loose-fill fibreglass, printed August 2026, says “Convection in glass loosefill insulation installed in open attics can reduce its thermal performance in extreme winter temperatures”. That is a current manufacturer’s sheet, not the 1991 test, so this section gives the loose-fill fibreglass manufacturers’ own lines on the cold, the density and the settled thickness, each with the document behind it. Open “The research behind this line” under any bullet for the document, the page and the test details.
“Convection in glass loosefill insulation installed in open attics can reduce its thermal performance in extreme winter temperatures.”
The manufacturers’ association puts the 1991 result down to how light the test installs were and says the products on sale have changed since.
“the fiber glass loose-fill insulations on the market today are not representative of what happened during the testing”
What the manufacturers’ documents say, with the research behind each line:
- The Insulation Institute (NAIMA) says the tested fibreglass was installed light. The tests it describes were on loose-fill fibreglass “intentionally installed improperly at a lighter density than the manufacturers specify”, the R-value “began to degrade” once the roof space “dropped below 12°F” (−11°C), “NAIMA members now formulate products and installation guidance specifically for colder climates”, and “when loose-fill insulation is installed at the proper density the R-value does not decrease” (“Loose Fill Insulation Performance and Convection”, paragraphs 2 and 3).
The research behind this line
- Document: Insulation Institute (NAIMA) web article “Loose Fill Insulation Performance and Convection”, paragraphs 2 and 3, undated. Its one footnote is Energy Design Update, “Good News on Attic Fiberglass Performance”, January 1992. Insulation Institute article (archived copy).
- Who ran it, who paid: the article says “a series of tests were completed” and “Researchers estimate” without naming the laboratory, the sponsor or the product. NAIMA is the trade association of the North American fibreglass, rock and slag wool manufacturers, so the page is the manufacturers’ own account.
- Year: “several years ago” before the January 1992 article it cites.
- Product and conditions: loose-fill fibreglass installed “at a lighter density than the manufacturers specify”, in a roof space that “dropped below 12°F”. No density figure and no brand.
- Result: the R-value “began to degrade”; at the proper density “the R-value does not decrease (in fact, the R-value increases at lower temperature)”; the extra heating cost at the light density “would only be $20 (1992 dollars) per year” for a home in the northern United States.
- What it does not show: which tests these were (the page does not name Oak Ridge, and the Oak Ridge paper gives its own installed densities of 6.4 to 9.0 kg/m³ in Table 1, blown in by a local contractor), any chart or measured figure for today’s products, any Australian product, or settling.
- Owens Corning says the cause was the shape of the pieces, and its own chart holds R-value to −40°F. Green Building Advisor (Allison Bailes, 9 January 2019) reports Owens Corning’s technical bulletin: in the early 1990s its loose-fill was made by “cutting it into little cubes”, “The bonded cubes did not nest well”, and “After changing their product, Owens Corning has measured the R-value versus attic temperature”, with “the measured R-value is above the labeled R-value for each thickness and at temperatures all the way down to -40°F”.
The research behind this line
- Document: Green Building Advisor, “Does Fiberglass Attic Insulation Really Lose R-Value?”, Allison A. Bailes III, 9 January 2019, sections “Not all fiberglass is the same” and “Fiberglass industry research on R-value”. The same article is on the author’s Energy Vanguard blog, 7 January 2019. Green Building Advisor article (archived copy).
- Who ran it, who paid: Owens Corning, in its own technical bulletin. The article says “at least two fiberglass insulation manufacturers have written technical bulletins about their product” with data measured “under conditions similar to those used in the Oak Ridge study”. Manufacturer-funded. The bulletin is not published on the Owens Corning site; the author offers it in a shared folder, which we have not read, so the figures here are the article’s reading of the chart.
- Year: the bulletin is undated in the article; the article is 2019.
- Product: Owens Corning’s redesigned unbonded loose-fill fibreglass at four thicknesses. The article gives no brand name and no installed density for the chart.
- Conditions: “conditions similar to those used in the Oak Ridge study”, roof-space temperatures down to −40°F (−40°C).
- Result: “the measured R-value is above the labeled R-value for each thickness” and “the R-value increases as the temperature drops until you get below 0°F”.
- What it does not show: independent confirmation. The author writes “They do have a vested interest, after all” and “If I find some independent research corroborating the OC and JM data, I’ll be sure to share it here.” No Australian product and no settling.
- Johns Manville’s chart peaks and eases at low density and keeps rising at 0.9 pcf. The same article reports Johns Manville’s bulletin: for both of its densities the R-value “starts at 100% with an attic temperature in the low 40s Fahrenheit and rises as the temperature drops”; the low-density product “hits a peak of nearly 125% at a temperature of about -15°F and then begins to drop”, “hitting about 107% at -40°F”; and “JM’s high-density (0.9 pcf) loose-fill fiberglass keeps rising all the way down to -40°F” (0.9 pcf is about 14 kg/m³).
The research behind this line
- Document: the same Green Building Advisor article, section “Fiberglass industry research on R-value” (the two Johns Manville graphs) and “Not all fiberglass is the same”. Green Building Advisor article (archived copy).
- Who ran it, who paid: Johns Manville, in its own technical bulletin. Manufacturer-funded. Not read by us; the figures are the article’s reading of the two graphs.
- Year: undated in the article; the article is 2019.
- Product: Johns Manville loose-fill fibreglass at a lower and a higher density (the higher given as 0.9 pcf, about 14 kg/m³). The article says the research was used to set “design specifications for all of Johns Manville’s loose-fill fiber glass attic insulations” and led to “maintaining an appropriate nodule or tuft size, which decreased the permeability of the installed insulation”.
- Conditions: roof-space temperatures from the low 40s Fahrenheit (about 5°C) down to −40°F (−40°C). Results are given as a percentage of the labelled R-value.
- Result: the low-density product peaks near 125% at about −15°F (−26°C) and is back to about 107% at −40°F; the 0.9 pcf product keeps rising to −40°F.
- What it does not show: independent confirmation (the author found none), the test method, the lower density’s figure, any Australian product, or settling.
- Johns Manville’s own attic card says the R-value “may start to decline” in extreme cold and adds depth in Minnesota. The Climate Pro attic card (BIC-162, April 2013), on its Minnesota page, says “fibrous insulation performance generally improves as attics get colder”, then “at extreme cold temperatures, the performance (R-value) of fiber glass insulation products may start to decline below the labeled value”, “Blown loose-fill insulation products are more susceptible to convection than batts”, “All loose-fill products perform differently” and “Johns Manville has extensively tested our attic insulation products at extreme cold temperatures”. Its table “Additional Climate Pro Needed to Attain R-value in Extremely Cold Temperatures” adds, for R-38 at a winter design temperature of −14 to −17°F (−26 to −27°C), 1 inch of depth and 1.3 bags per 1,000 square feet.
The research behind this line
- Document: Johns Manville, “JM Climate Pro Fiber Glass Blowing Wool” attic card, BIC-162 4/13, © 2013, reverse side “JM Climate Pro Fiber Glass Blowing Wool for Minnesota Only”. Johns Manville attic card (PDF) (archived copy).
- Who ran it, who paid: Johns Manville’s own card. The cold tests it mentions are not described on the card (no laboratory, method, temperatures or figures).
- Why the card exists: “FTC Trade Regulation Rule Part 460 specifies that all products be rated at 75˚F mean temperature” (24°C) and “Minnesota law requires an insulation product to be designed to provide its stated R-value at winter design temperatures”, so the card adds depth and bags for Minnesota’s design temperatures (−14°F at Winona to −31°F at Bemidji).
- Coverage chart: “Minimum installed thickness” and “Settled thickness”, defined as “Expected thickness after long-term settling has occured” [sic], print the same figure in every row (R-38: 13.8 inches and 13.8 inches).
- What it does not show: the test results, the temperature at which the decline starts, or any Australian product. The extra-depth table is the manufacturer’s allowance, not a measured loss. The card is dated 2013; later cards may differ.
- Owens Corning’s current data sheet says the labelled R-value is a winter average. The AttiCat PINK Blown-In Insulation Product Data Sheet (May 2026), under “Thermal Performance”, says “Convection in fiber glass loosefill insulation installed in open attics can reduce its thermal performance at extreme winter temperatures” and that the product “has been designed to anticipate this phenomenon and the labeled R-value reflects the average performance over the winter heating season”. Its coverage chart carries “(MINNESOTA ONLY*)” columns, 1.5 extra inches and 2.5 extra bags per 1,000 square feet for R-38 because “Minnesota Administrative Code requires insulation products to provide their stated R-value(s) at Winter Design Temperatures”.
The research behind this line
- Document: Owens Corning, “AttiCat PINK Blown-In Fiberglas Insulation” Product Data Sheet, May 2026, sections “Standards, Code Compliance”, the coverage chart with its Minnesota footnote, and “Thermal Performance”. Owens Corning AttiCat data sheet (PDF) (archived copy).
- Who ran it, who paid: Owens Corning’s own sheet. No cold test is named; the sheet says “R-values are determined in accordance with ASTM C687”, the standard laboratory method.
- Product and conditions: AttiCat PINK Blown-In Insulation, a North American loose-fill fibreglass “designed for use exclusively with the AttiCat machine”. No temperatures or figures are given for the winter dip.
- Result: none stated beyond the sentences quoted and the Minnesota columns.
- What it does not show: how much the R-value falls in extreme cold, at what temperature, or how the winter average was measured. It is not an Australian product.
- The coverage charts print the settled thickness equal to the installed thickness. Owens Corning’s L77 attic card lists “Minimum Initial Installed Thickness” and “Minimum Settled Thickness” at the same figure in every row (R-38: 13.25 and 13.25 inches), its AttiCat sheet does the same (R-38: 13.5 and 13.5 inches), and Johns Manville’s Climate Pro card does the same (R-38: 13.8 and 13.8 inches). The L77 card also says loose-fill insulations “vary in thermal performance due to factors such as aging, mean temperature, settlement, convection, moisture absorption and installation variation” and that “Failure by the installer to provide both the required bags and at least the minimum thickness” “will result in lower insulation R-value”.
The research behind this line
- Documents: Owens Corning, PROPINK L77 Loosefill Insulation attic card, Pub. No. 10012954-D, August 2026, “Attics” coverage chart and the two notes under the charts, L77 attic card (PDF) (archived copy); Owens Corning AttiCat Product Data Sheet, May 2026, coverage chart, AttiCat data sheet (PDF) (archived copy); Johns Manville Climate Pro attic card, BIC-162 4/13, coverage chart, Johns Manville attic card (PDF) (archived copy).
- Who ran it, who paid: the manufacturers’ own coverage charts, which set the installer’s minimums. No settling test, method or measured figure is given on any of the three.
- Product: PROPINK L77 (32 lb bag), AttiCat (27.5 lb bag) and Climate Pro (28.5 lb bag), all North American loose-fill fibreglass.
- Result: the settled minimum equals the installed minimum on every row of all three charts.
- What it does not show: whether or how much the product settles in a roof over years; the charts state a minimum, and the L77 note lists settlement among the factors that vary performance.
- Knauf lists Supafil Loft in Australia; its cold test and Australian settling figure were not found. Knauf’s Australian site lists Supafil Loft as “an unbonded, glasswool insulation” for “new build and existing ceilings”. Knauf’s European Technical Assessment for the sister products Supafil Loft Plus and Supafil Loft Pro (ETA-18/0707, DIBt, 5 June 2025) lists “Settling under impact excitation in the case of free placing” at “≤ 9 % at a minimum bulk density of 20 kg/m³ and a maximum thickness of 330 mm” without binders and ≤ 11% with, a free-placing bulk density of “20 kg/m³ to 23 kg/m³”, and for “Settling under defined climatic conditions” the entry “No performance assessed”.
The research behind this line
- Documents: Knauf Australia product page for Supafil Loft, knauf.com/en-AU (the page refuses automated reading, so the two phrases are as the page is indexed; its datasheet is listed there but unread). European Technical Assessment ETA-18/0707 of 5 June 2025, Deutsches Institut für Bautechnik (DIBt), English translation, section 3 table rows “Bulk density”, “Settlement” and “Airflow resistance”. ETA-18/0707 (PDF) (archived copy).
- Who ran it, who paid: the assessment is issued by DIBt “on the basis of agreed data/ information, deposited with Deutsches Institut für Bautechnik” by the manufacturer, so it is Knauf’s data under a European assessment body’s seal.
- Product: “Supafil Loft Plus” and “Supafil Loft Pro”, unbonded loose glass mineral wool, European products. The Australian Supafil Loft is not named in the assessment.
- Conditions and result: free placing on a ceiling or between beams at 20 to 23 kg/m³; settling under impact excitation ≤ 9% (no binder) or ≤ 11% (with binder) at a minimum 20 kg/m³ and a maximum thickness of 330 mm; airflow resistance “≥ 10,0 kPa·s/m² at a minimum bulk density of 20 kg/m³”; declared conductivity 0.037 W/(m·K).
- What it does not show: a cold R-value test for any Supafil product (not found), the Australian Supafil Loft’s own figures, or long-term settling in a roof (the climatic-conditions row is “No performance assessed”).
What the independent tests covered
Show the test details
- Who, for whom: Oak Ridge National Laboratory for the US Department of Energy, 1991 to 1992, with Attic Seal Inc. and the Cellulose Industry Standards Enforcement Program as co-sponsors. The University of Illinois test was sponsored by a fibreglass manufacturer (Energy Design Update, October 1991).
- Covered: one 1991 loose-fill fibreglass, four specimens at 6.4 to 9.0 kg/m³; unfaced R-19 fibreglass batts; one loose-fill cellulose fibre insulation at 30 to 34 kg/m³; a ventilated full-size roof-space module held at steady settings from 7°C to −28°C.
- Not covered: any loose-fill fibreglass made after 1992, including the redesigned products the manufacturers describe above; any Australian product; the manufacturers’ −40°F charts, which the 2019 article’s author was still waiting to see repeated by an independent laboratory; settling over years; a summer roof.
- Source: Wilkes and Childs 1992, Tables 1 and 3; Green Building Advisor, 9 January 2019 (archived copy).
So the manufacturers say the 1991 installs were light, today’s products are different, and their own measurements hold at or above the labelled R-value down to −40°F. Their current sheets say convection in an open roof space can reduce performance in extreme winter temperatures, and their coverage charts print the settled thickness equal to the installed thickness. The independent measurements on this page stop at 1992, and the author who reproduced the manufacturers’ charts was still looking for independent confirmation in 2019. If someone offers to blow fibreglass into your roof, ask the manufacturer for cold-test evidence that beats the Oak Ridge result before it goes in your roof.
Why loose-fill fibreglass loses R-value
The cause is convection, the same thing that happens in a pot on the stove. When the top of a loose, open insulation is cold and the bottom is warm, the air inside it circulates in loops, and those loops carry heat up through the fibre far faster than still air would (Energy Design Update, October 1991). Loose-fill fibreglass is glass fibre chopped into small tufts and blown into the roof space through a hose, so it goes in light and open, and that open air is where the loops get going.
Our premium cellulose insulation goes in as a dense mat of fibres that grip each other, so it stays put when air moves across it. The video beside this paragraph is a finished job of ours with a fan running in the roof space, and the insulation does not move around.
Oak Ridge showed the cause by laying batts over the top of the loose fibreglass, which brought the R-value back to about the sum of the two (R38.8 to R41.7, Table 3) by stopping the loops. A Swedish study found the same convection starting in low-density materials only, with the onset at a modified Rayleigh number of about 22 to 25 (Wahlgren, Chalmers University of Technology).
The paper also prints the air permeability of each material. The loose-fill fibreglass it tested let air through at 6.7×10⁻⁷ to 1.0×10⁻⁶ ft², against 2×10⁻⁸ to 7×10⁻⁸ ft² for loose-fill cellulose fibre insulation (Wilkes and Childs 1992, sections “Loose-Fill Fiberglass Insulation Only” and “Loose-Fill Cellulose Insulation”, quoting Yarbrough 1990). Worked out from those figures, that loose-fill fibreglass was roughly 10 to 50 times more open to air than cellulose fibre insulation. A light, open layer lets the air it holds start circulating on the coldest nights, which is when your heating bill is highest. On a summer afternoon the hot side is on top, the air inside the insulation sits still, and the loops don’t form, which is why this is a winter question.

Peter’s own video
Finished cellulose fibre insulation job with Cardifair running but the insulation does not move around
Watch on YouTube →

Demonstration video
Air Infiltration Display
Nu-Wool · Watch on YouTube →
Our premium cellulose insulation goes in at about 35 kg/m³, two to four times as dense as most glasswool batts (CSIRO lists glass fibre batts at 8 to 16 kg/m³). This isn’t a lab test. It’s a demonstration of the difference you can see between the two products. Air Infiltration Display, by Nu-Wool, a US cellulose fibre insulation manufacturer.
About this study
Show the test details
- Who, for whom: Paula Wahlgren, Chalmers University of Technology, Gothenburg, Sweden; doctoral research on convection in roof-space insulation, cited here from its published abstract.
- Product tested: loose-fill roof-space insulation across a range of densities, heated from below with a cold top, as in a winter roof space.
- Result: “natural convection occurs in low-density materials only”, with the onset at a modified Rayleigh number of about 22 to 25.
- What it does not show: any Australian product, or a loss figure for any named product.
- Source: Chalmers research record, abstract.
Loose-fill fibreglass in Australia today
Loose-fill fibreglass is sold here. Knauf Insulation, whose Australian head office is at Cannon Hill in Brisbane, lists Supafil Loft on its Australian site as an unbonded glasswool for new and existing ceilings, blown in with a dedicated machine. The manufacturers say today’s loose-fill fibreglass is a redesigned product, and their own charts show no loss down to −40°C (Insulation Institute, the manufacturers’ association; Owens Corning and Johns Manville data reported by Green Building Advisor as the manufacturers’ own; their lines and the research behind each are in What the manufacturers say above). The government laboratory tests on this page are from 1991 and 1992 and tested the products of that day.
Peter JohnsonComfort Zone Insulation Team
“If someone offers to blow fibreglass into your roof, ask the manufacturer for cold-test evidence that beats the Oak Ridge result before it goes in your roof.”
That is a fair question for any product, ours included, and the next section shows why the cold matters more in some postcodes than others.
How cold roofs really get
Oak Ridge measured the onset of the loss at about an 18°C difference between the room and the top of the insulation, and the 35 to 50% loss at a 39 to 42°C difference, for the loose-fill fibreglass it tested. Against a room heated to 20°C, here is what that means where Australians feel the cold.
Katoomba in the Blue Mountains averages a July minimum of 2.6°C (Bureau of Meteorology, Katoomba climate statistics), so an ordinary July night there sits right at the onset. Stanthorpe on the Granite Belt holds Queensland’s record low of −10.6°C, set on 23 June 1961 (Bureau of Meteorology, Stanthorpe climate statistics). That is a 30.6°C difference, well past the onset and still short of the band where the tested product lost 35 to 50%. Charlotte Pass in the Snowy Mountains holds the national record of −23°C, set on 29 June 1994 (Weatherzone, “Australia’s lowest temperatures”), a 43°C difference, beyond the far end of that band.
Those are record lows and most nights are far milder. A roof space under a clear sky can run colder than the weather station’s screen, and a room heated to 22°C widens the difference, so the real gap on a given night can be larger than the thermometer outside suggests. The Oak Ridge authors said themselves that in mild climates the findings are probably irrelevant (Energy Design Update, October 1991), so on the Brisbane coast the thing to worry about is gaps. Up the range, in Toowoomba, the Downs and the Granite Belt, it is the right question to ask before anyone blows loose fibreglass into your roof. Our climate-zone R-value guide gives the depth each zone needs.

How far below a 20°C room each place gets
Why cellulose fibre holds its R-value
Our premium cellulose insulation goes in at about 35 kg/m³, two to four times as dense as most glasswool batts (CSIRO lists glass fibre batts at 8 to 16 kg/m³). At that density our premium cellulose insulation resists air moving through it, so it doesn’t lose performance to air currents in the roof the way loose fibreglass can, and your home holds its temperature through extreme summers and freezing winters. The Oak Ridge figures put loose-fill cellulose fibre insulation at roughly 10 to 50 times less air-permeable than the loose-fill fibreglass it tested (Wilkes and Childs 1992, permeability figures above), and the cellulose it tested went in at 30 to 38 kg/m³, the same range as ours.
Your R-value comes from the settled depth of our premium cellulose insulation, so that’s what we measure and what you can check. Our standard ceiling is a settled 120 mm from the ceiling, which gives about R3.0 and keeps the roof heat off your rooms in summer and the warmth in through winter. I’ve never come back to a job for settling; the jobs I’ve come back to were pumped in short, and a top-up fixed them. Our guide on existing cellulose insulation shows what a short job looks like and how a top-up fixes it.

Polyester underfloor batts in the cold
Peter JohnsonComfort Zone Insulation Team
“Under a floor it’s cold air moving across the open underside of the insulation, and in my experience a denser polyester batt stands up to it far better than a light fibreglass one, which is why our custom polyester floor batts are what we fit under floors. They’re made for each job, usually the morning before we install them, and they’re never held more than about a week, so they go in at the thickness they were made to.”
That is my view from the jobs we do, not a test result. Our polyester underfloor batts guide covers how they hold themselves up, what mop water does to them and why there is no itch.

Ask before you book
Four things to ask any installer, and the answers we give.
- The exact product and its installed density, on the quote. Our quote names our premium cellulose insulation, and it goes in at about 35 kg/m³ settled.
- An independent cold test for that product. Oak Ridge tested loose-fill cellulose fibre insulation at 30 to 38 kg/m³ and it gained R-value as the roof got colder; the papers are linked above.
- The settled depth and how it is measured. We put the settled depth on your certificate, measured from the ceiling, so you can check it with a ruler from the manhole against our depth tables.
- What the certificate records. Ours records the product, the settled depth and the R-value from our depth tables, so the answer is on paper before we start.
If you are on the Downs, the Granite Belt or anywhere the frost settles, get a fixed-price quote from us online and we’ll put the settled depth and the R-value on it before you decide. Our premium cellulose insulation goes in at the density that gained R-value in the cold test, and it carries our Comfort Zone™ Life-of-House Guarantee.

All of the Comfort. None of the gaps, pests, mould or itch. Make your home a Comfort Zone today. Ask us how.
Cold-roof insulation questions answered
Does insulation lose R-value in the cold?
Cellulose fibre insulation did not in the Oak Ridge tests; it gained R-value from R-18 to R-20.3 as the outside air fell from 4°C to −28°C (Energy Design Update, October 1991). The loose-fill fibreglass tested lost about 35 to 50% at a 39 to 42°C difference (Wilkes and Childs, ORNL 1992, Abstract). Ask for the cold test on any blown-in fibreglass before it goes in.
Does blown-in fibreglass insulation lose R-value over time?
Settling and cold are two different questions. The Oak Ridge loss was driven by temperature, measured at steady cold settings. Settling is a separate matter, so ask the manufacturer for its settled-thickness data as well as the cold test.
Is cellulose fibre or loose-fill fibreglass better in a roof space?
On the Oak Ridge numbers, cellulose fibre insulation held its R-value in the cold and the loose-fill fibreglass tested lost 35 to 50% at the coldest settings. At 35 kg/m³ our premium cellulose insulation packs about four to seven times as much solid material into the same space as a glasswool batt (worked out from CSIRO’s density figures: ours at 35 kg/m³, glass fibre batts at 8 to 16 kg/m³), which is why our premium cellulose insulation holds its depth under its own weight and slows air moving through it.
Which insulation is best for a cold climate in Australia?
Depth decides R-value, so start with the R-value for your zone on our climate-zone R-value guide and ask for the settled depth that gives it. On a frost night the product also has to hold that R-value, and the cellulose fibre insulation Oak Ridge tested gained R-value as it got colder.
Does this cold loss happen in summer?
No. The loops form when the insulation is warm underneath and cold on top, which is a winter roof. On a summer afternoon the hot side is on top and the air inside the insulation sits still. Summer losses come from radiant heat and gaps, which our other guides cover.
What about underfloor in a cold area?
Under a floor it’s cold air moving across the open underside of the insulation, and in my experience a denser polyester batt stands up to it far better than a light fibreglass one. That’s my view from the jobs we do, and our polyester underfloor batts guide covers the rest.